CVE-2022-28893

CVSS v3.1 7.8 (High)
78% Progress
CVSS v2.0 7.2 (High)
72% Progress
EPSS 0.04 % (15th)
0.04% Progress
Affected Products 22
Advisories 21

The SUNRPC subsystem in the Linux kernel through 5.17.2 can call xs_xprt_free before ensuring that sockets are in the intended state.

Weaknesses
CWE-416
Use After Free
CVE Status
PUBLISHED
CNA
MITRE
Published Date
2022-04-11 05:15:07
(2 years ago)
Updated Date
2023-05-15 18:45:04
(16 months ago)

Affected Products

Loading...
Loading...

Configuration #1

AND
    CPE23 From Up To
OR  
  Linux Kernel from 5.1 version and prior 5.4.196 version cpe:2.3:o:linux:linux_kernel >= 5.1 < 5.4.196
OR  
  Running on/with
  Linux Kernel from 5.5 version and prior 5.10.117 version cpe:2.3:o:linux:linux_kernel >= 5.5 < 5.10.117
OR  
  Running on/with
  Linux Kernel from 5.11 version and prior 5.15.41 version cpe:2.3:o:linux:linux_kernel >= 5.11 < 5.15.41
OR  
  Running on/with
  Linux Kernel from 5.16 version and prior 5.16.20 version cpe:2.3:o:linux:linux_kernel >= 5.16 < 5.16.20
OR  
  Running on/with
  Linux Kernel from 5.17 version and prior 5.17.3 version cpe:2.3:o:linux:linux_kernel >= 5.17 < 5.17.3

Configuration #2

AND
    CPE23 From Up To
OR  
  Netapp Solidfire, Enterprise Sds & Hci Storage Node cpe:2.3:a:netapp:solidfire\%2c_enterprise_sds_\%26_hci_storage_node:-
OR  
  Running on/with
  Netapp Solidfire & Hci Management Node cpe:2.3:a:netapp:solidfire_\%26_hci_management_node:-

Configuration #3

AND
    CPE23 From Up To
OR  
  Netapp Hci Compute Node Firmware cpe:2.3:o:netapp:hci_compute_node_firmware:-
OR  
  Running on/with
  Netapp Hci Compute Node cpe:2.3:h:netapp:hci_compute_node:-

Configuration #4

AND
    CPE23 From Up To
OR  
  Netapp H300s Firmware cpe:2.3:o:netapp:h300s_firmware:-
OR  
  Running on/with
  Netapp H300s cpe:2.3:h:netapp:h300s:-

Configuration #5

AND
    CPE23 From Up To
OR  
  Netapp H500s Firmware cpe:2.3:o:netapp:h500s_firmware:-
OR  
  Running on/with
  Netapp H500s cpe:2.3:h:netapp:h500s:-

Configuration #6

AND
    CPE23 From Up To
OR  
  Netapp H700s Firmware cpe:2.3:o:netapp:h700s_firmware:-
OR  
  Running on/with
  Netapp H700s cpe:2.3:h:netapp:h700s:-

Configuration #7

AND
    CPE23 From Up To
OR  
  Netapp H300e Firmware cpe:2.3:o:netapp:h300e_firmware:-
OR  
  Running on/with
  Netapp H300e cpe:2.3:h:netapp:h300e:-

Configuration #8

AND
    CPE23 From Up To
OR  
  Netapp H500e Firmware cpe:2.3:o:netapp:h500e_firmware:-
OR  
  Running on/with
  Netapp H500e cpe:2.3:h:netapp:h500e:-

Configuration #9

AND
    CPE23 From Up To
OR  
  Netapp H700e Firmware cpe:2.3:o:netapp:h700e_firmware:-
OR  
  Running on/with
  Netapp H700e cpe:2.3:h:netapp:h700e:-

Configuration #10

AND
    CPE23 From Up To
OR  
  Netapp H410s Firmware cpe:2.3:o:netapp:h410s_firmware:-
OR  
  Running on/with
  Netapp H410s cpe:2.3:h:netapp:h410s:-

Configuration #11

AND
    CPE23 From Up To
OR  
  Netapp H410c Firmware cpe:2.3:o:netapp:h410c_firmware:-
OR  
  Running on/with
  Netapp H410c cpe:2.3:h:netapp:h410c:-

Configuration #12

AND
    CPE23 From Up To
OR  
  Debian Linux 11.0 cpe:2.3:o:debian:debian_linux:11.0
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...