CVE-2019-19816

CVSS v3.1 7.8 (High)
78% Progress
CVSS v2.0 9.3 (High)
93% Progress
EPSS 0.12 % (47th)
0.12% Progress
Affected Products 18
Advisories 6

In the Linux kernel 5.0.21, mounting a crafted btrfs filesystem image and performing some operations can cause slab-out-of-bounds write access in __btrfs_map_block in fs/btrfs/volumes.c, because a value of 1 for the number of data stripes is mishandled.

Weaknesses
CWE-787
Out-of-bounds Write
CVE Status
PUBLISHED
CNA
MITRE
Published Date
2019-12-17 06:15:12
(4 years ago)
Updated Date
2023-01-19 16:05:05
(20 months ago)

Affected Products

Loading...
Loading...

Configuration #1

AND
    CPE23 From Up To
OR  
  Linux Kernel from 2.6.12 version and prior 4.4.247 version cpe:2.3:o:linux:linux_kernel >= 2.6.12 < 4.4.247
OR  
  Running on/with
  Linux Kernel from 4.5 version and prior 4.9.247 version cpe:2.3:o:linux:linux_kernel >= 4.5 < 4.9.247
OR  
  Running on/with
  Linux Kernel from 4.10 version and prior 4.14.210 version cpe:2.3:o:linux:linux_kernel >= 4.10 < 4.14.210
OR  
  Running on/with
  Linux Kernel from 4.15 version and prior 4.19.137 version cpe:2.3:o:linux:linux_kernel >= 4.15 < 4.19.137
OR  
  Running on/with
  Linux Kernel from 4.20 version and prior 5.2 version cpe:2.3:o:linux:linux_kernel >= 4.20 < 5.2

Configuration #2

AND
    CPE23 From Up To
OR  
  Canonical Ubuntu Linux 14.04 cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:esm
OR  
  Running on/with
  Canonical Ubuntu Linux 16.04 cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts
OR  
  Running on/with
  Canonical Ubuntu Linux 18.04 cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts

Configuration #3

AND
    CPE23 From Up To
OR  
  Debian Linux 9.0 cpe:2.3:o:debian:debian_linux:9.0

Configuration #4

AND
    CPE23 From Up To
OR  
  Netapp Active Iq Unified Manager for Vmware Vsphere from 9.5 version cpe:2.3:a:netapp:active_iq_unified_manager::*:*:*:*:vmware_vsphere >= 9.5
OR  
  Running on/with
  Netapp Data Availability Services cpe:2.3:a:netapp:data_availability_services:-
OR  
  Running on/with
  Netapp Hci Management Node cpe:2.3:a:netapp:hci_management_node:-
OR  
  Running on/with
  Netapp Solidfire cpe:2.3:a:netapp:solidfire:-
OR  
  Running on/with
  Netapp Steelstore Cloud Integrated Storage cpe:2.3:a:netapp:steelstore_cloud_integrated_storage:-

Configuration #5

AND
    CPE23 From Up To
OR  
  Netapp Aff A700s Firmware cpe:2.3:o:netapp:aff_a700s_firmware:-
OR  
  Running on/with
  Netapp Aff A700s cpe:2.3:h:netapp:aff_a700s:-

Configuration #6

AND
    CPE23 From Up To
OR  
  Netapp Fas8300 Firmware cpe:2.3:o:netapp:fas8300_firmware:-
OR  
  Running on/with
  Netapp Fas8300 cpe:2.3:h:netapp:fas8300:-

Configuration #7

AND
    CPE23 From Up To
OR  
  Netapp Fas8700 Firmware cpe:2.3:o:netapp:fas8700_firmware:-
OR  
  Running on/with
  Netapp Fas8700 cpe:2.3:h:netapp:fas8700:-

Configuration #8

AND
    CPE23 From Up To
OR  
  Netapp Aff A400 Firmware cpe:2.3:o:netapp:aff_a400_firmware:-
OR  
  Running on/with
  Netapp Aff A400 cpe:2.3:h:netapp:aff_a400:-

Configuration #9

AND
    CPE23 From Up To
OR  
  Netapp H610s Firmware cpe:2.3:o:netapp:h610s_firmware:-
OR  
  Running on/with
  Netapp H610s cpe:2.3:h:netapp:h610s:-
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...