CVE-2019-19057

CVSS v3.1 3.3 (Low)
33% Progress
CVSS v2.0 2.1 (Low)
21% Progress
EPSS 0.05 % (19th)
0.05% Progress
Affected Products 20
Advisories 38

Two memory leaks in the mwifiex_pcie_init_evt_ring() function in drivers/net/wireless/marvell/mwifiex/pcie.c in the Linux kernel through 5.3.11 allow attackers to cause a denial of service (memory consumption) by triggering mwifiex_map_pci_memory() failures, aka CID-d10dcb615c8e.

Weaknesses
CWE-401
Missing Release of Memory after Effective Lifetime
CVE Status
PUBLISHED
CNA
MITRE
Published Date
2019-11-18 06:15:12
(4 years ago)
Updated Date
2023-11-07 03:07:24
(10 months ago)

Affected Products

Loading...
Loading...

Configuration #1

    CPE23 From Up To
  Linux Kernel 5.3.11 and prior versions cpe:2.3:o:linux:linux_kernel <= 5.3.11

Configuration #2

    CPE23 From Up To
  Canonical Ubuntu Linux 14.04 cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:esm
  Canonical Ubuntu Linux 16.04 cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:esm
  Canonical Ubuntu Linux 18.04 cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts
  Canonical Ubuntu Linux 19.10 cpe:2.3:o:canonical:ubuntu_linux:19.10
  Debian Linux 8.0 cpe:2.3:o:debian:debian_linux:8.0
  Fedoraproject Fedora 30 cpe:2.3:o:fedoraproject:fedora:30
  Fedoraproject Fedora 31 cpe:2.3:o:fedoraproject:fedora:31
  Opensuse Leap 15.1 cpe:2.3:o:opensuse:leap:15.1

Configuration #3

    CPE23 From Up To
  Netapp Active Iq Unified Manager for Vmware Vsphere cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere
  Netapp Aff Baseboard Management Controller cpe:2.3:a:netapp:aff_baseboard_management_controller:-
  Netapp Cloud Backup cpe:2.3:a:netapp:cloud_backup:-
  Netapp Data Availability Services cpe:2.3:a:netapp:data_availability_services:-
  Netapp E-series Santricity Os Controller 11.0 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.0
  Netapp E-series Santricity Os Controller 11.0.0 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.0.0
  Netapp E-series Santricity Os Controller 11.20 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.20
  Netapp E-series Santricity Os Controller 11.25 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.25
  Netapp E-series Santricity Os Controller 11.30 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.30
  Netapp E-series Santricity Os Controller 11.30.5r3 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.30.5r3
  Netapp E-series Santricity Os Controller 11.40 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.40
  Netapp E-series Santricity Os Controller 11.40.3r2 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.40.3r2
  Netapp E-series Santricity Os Controller 11.40.5 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.40.5
  Netapp E-series Santricity Os Controller 11.50.1 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.50.1
  Netapp E-series Santricity Os Controller 11.50.2 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.50.2:-
  Netapp E-series Santricity Os Controller 11.50.2 P1 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.50.2:p1
  Netapp E-series Santricity Os Controller 11.60 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.60
  Netapp E-series Santricity Os Controller 11.60.0 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.60.0
  Netapp E-series Santricity Os Controller 11.60.1 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.60.1
  Netapp E-series Santricity Os Controller 11.60.3 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.60.3
  Netapp E-series Santricity Os Controller 11.70.1 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.70.1
  Netapp E-series Santricity Os Controller 11.70.2 cpe:2.3:a:netapp:e-series_santricity_os_controller:11.70.2
  Netapp Fas/aff Baseboard Management Controller cpe:2.3:a:netapp:fas\%2faff_baseboard_management_controller:-
  Netapp Hci Baseboard Management Controller H610s cpe:2.3:a:netapp:hci_baseboard_management_controller:h610s
  Netapp Solidfire, Enterprise Sds & Hci Storage Node cpe:2.3:a:netapp:solidfire\%2c_enterprise_sds_\%26_hci_storage_node:-
  Netapp Solidfire & Hci Management Node cpe:2.3:a:netapp:solidfire_\%26_hci_management_node:-
  Netapp Steelstore Cloud Integrated Storage cpe:2.3:a:netapp:steelstore_cloud_integrated_storage:-
  Broadcom Brocade Fabric Operating System Firmware cpe:2.3:o:broadcom:brocade_fabric_operating_system_firmware:-

Configuration #4

AND
    CPE23 From Up To
OR  
  Netapp Hci Compute Node Firmware cpe:2.3:o:netapp:hci_compute_node_firmware:-
OR  
  Running on/with
  Netapp Hci Compute Node cpe:2.3:h:netapp:hci_compute_node:-

Configuration #5

AND
    CPE23 From Up To
OR  
  Netapp Solidfire Baseboard Management Controller Firmware cpe:2.3:o:netapp:solidfire_baseboard_management_controller_firmware:-
OR  
  Running on/with
  Netapp Solidfire Baseboard Management Controller cpe:2.3:h:netapp:solidfire_baseboard_management_controller:-
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...